Lithium Argyrodite LPSC Solid Electrolyte
High-conductivity argyrodite powder for cold-pressed all-solid-state cell development.
Li₆PS₅Cl is a sulfide solid electrolyte valued for high room-temperature ionic conductivity and favorable mechanical contact under pressure. It is supplied in sealed, moisture-controlled packaging for glovebox transfer.
- Application
- Solid-State Battery Materials →
- Sample
- 10 g / 25 g / 100 g
- Dispatch
- Confirm by product, quantity and destination
Choose the closest direction.
These choices help us understand the inquiry. They are not guaranteed inventory or specifications; availability varies by product and source.
Availability differs by product. Ask us to confirm the exact documents for this inquiry.
Composition option
- Li₆PS₅Cl
- Chloride-rich argyrodite
- Other sulfide — inquire
Powder option
- Standard powder
- Fine powder — inquire
Sample quantity
- 10 g
- 25 g
- 100 g
| Exact composition / grade | Varies by selected product and source |
|---|---|
| Purity / particle-size data | Ask for the available specification |
| Performance test data | Method and availability must be confirmed |
| COA / SDS / other files | Availability differs by product; inquire specifically |
Typical screening context—not a supplied-lot specification.
These values describe common research-grade directions and help buyers formulate an inquiry. They are not a quotation, acceptance specification or guarantee. Before purchase, every value must be checked against the selected supplier specification; after a lot is assigned, use the lot-specific COA or test report where available.
| Crystal family | Argyrodite |
|---|---|
| D50 | 3–10 μm |
| Purity | ≥99% |
| Ionic conductivity | ≥2 mS/cm at 25°C, typical pellet |
| Moisture exposure | Avoid; hydrolysis can release H₂S |
Reference values are editorial context only. Actual options, methods, tolerances and documents vary by source and selected product.
Where this grade enters the workflow.
Glovebox use is required. Avoid all contact with moisture and review the SDS before opening.
Four items confirmed separately.
10 g / 25 g / 100 g
Confirm the selected grade and quantity by inquiry.
Depends on product, source and destination.
Quoted and confirmed for each product separately.
Send me the options for LPSC electrolyte.
Leave your name, work email and organization. Choose whether you need grade options, sample pricing or available product documents.
Questions technical buyers ask first.
Does LPSC require glovebox handling?+
Yes. LPSC is moisture sensitive and should be opened and processed under a dry inert atmosphere. For a reproducible evaluation of LPSC electrolyte, confirm the selected grade, test method, packaging condition and assigned-lot evidence rather than applying a general catalogue statement to every source. State the acceptance point in your inquiry, including any composition, particle-size, moisture, handling or performance limit that matters to your process. Available specifications and documents differ by source, so the quotation should identify what can be confirmed before shipment.
How is conductivity reported?+
Test conditions and report availability differ by source. Ask us to confirm the method, temperature and pellet conditions for the selected option. For a reproducible evaluation of LPSC electrolyte, confirm the selected grade, test method, packaging condition and assigned-lot evidence rather than applying a general catalogue statement to every source. State the acceptance point in your inquiry, including any composition, particle-size, moisture, handling or performance limit that matters to your process. Available specifications and documents differ by source, so the quotation should identify what can be confirmed before shipment.
Can I order 10 g first?+
10 g is listed as an inquiry option for selected grades. Confirm actual availability and price before ordering. For a reproducible evaluation of LPSC electrolyte, confirm the selected grade, test method, packaging condition and assigned-lot evidence rather than applying a general catalogue statement to every source. State the acceptance point in your inquiry, including any composition, particle-size, moisture, handling or performance limit that matters to your process. Available specifications and documents differ by source, so the quotation should identify what can be confirmed before shipment.
Why is there no public price or stock status for LPSC electrolyte?+
iChangly handles LPSC electrolyte as a technical sourcing inquiry rather than a fixed retail listing. Price and availability can change with the selected composition or grade, particle-size direction, evaluation quantity, supplier, assigned lot, packaging, destination and shipping route. A catalogue price or an automatic in-stock label would therefore be easy to misread as a firm offer. Send the closest product option, quantity and destination instead. The reply will identify which options can currently be sourced, what documents can be reviewed, the applicable quotation and whether the requested delivery route needs additional handling or transport review.
Which specifications should I include when requesting LPSC electrolyte?+
Start with the cell system or synthesis route, the quantity needed for screening, and the variables that could cause a failed experiment. For LPSC electrolyte, list the composition or grade direction, particle-size or physical-form requirement, any impurity or moisture limits, and the test method behind a performance target. Also state the receiving atmosphere, pack preference and destination. This lets the sourcing review distinguish a useful acceptance requirement from a catalogue value and confirm which items are available for the selected source before quotation.
Which documents can be supplied with LPSC electrolyte?+
Document availability is confirmed for the selected product and source, not assumed across the entire catalogue. Ask separately for the supplier specification, SDS, assigned-lot COA or test report, particle-size or phase data, and any transport files required for the destination. Some documents may only exist after a lot is assigned or an order is accepted. The quotation should state which files can be reviewed before purchase and which accompany shipment, so the laboratory does not treat a general product sheet as lot-specific evidence.
How should LPSC be stored and how long does it remain usable?+
LPSC should remain sealed in moisture-barrier packaging and be opened only in a suitably dry inert environment because moisture exposure can change sulfide chemistry and may generate hazardous decomposition products. Storage life cannot be assigned from the family name alone; it depends on the supplier’s packaging, residual moisture, seal integrity, storage temperature and how often the container is opened. Request the selected source’s storage statement and SDS, divide material into working aliquots when appropriate, record opening dates, and check phase or conductivity again if exposure or a long storage interval could affect the experiment.
What pressing pressure is typically used to make LPSC pellets for testing?+
Research reports use a wide pressure range, commonly from tens to several hundred megapascals, because particle size, die geometry, dwell time and whether pressure is maintained during measurement all influence pellet contact. A higher pressure may lower apparent resistance by improving particle contact, but it can also make comparisons misleading if another material was tested at a different pressure. Report the forming pressure, stack pressure, pellet thickness, density, electrode arrangement and temperature with every conductivity value. Select a pressure that the intended cell architecture can reproduce rather than optimizing only a laboratory pellet number.
Is LPSC compatible with lithium-metal anodes without a coating?+
Direct contact is an active research area rather than a universal compatibility claim. Sulfide electrolytes can form interphases against lithium metal, and the resulting resistance or stability depends on composition, current density, pressure, surface condition and cycling protocol. Protective interlayers, alloy layers or modified electrolyte surfaces are often investigated to control this interface. Before selecting a grade, define whether the experiment studies an uncoated reference or a protected interface, then compare cells using the same pressure, areal capacity and formation procedure. Supplier powder data alone cannot guarantee lithium-metal cycling performance.